InspectMind AI logo InspectMind
Back to Case Studies
Student HousingWood FrameMultifamily

1,497 Issues Found in Student Housing Project

Critical wood framing conflicts, placeholder text in structural details, and coordination issues across multiple buildings—surfaced before construction began.

1,497
Issues Found
2021 IBC
Code Referenced
4
Disciplines

Key Finding: Placeholder Text in Structural Details

Simpson hanger model numbers showed "XXXXX" placeholder text—indicating incomplete design documents that would have halted procurement and delayed construction.

The Project

A large-scale student housing development featuring multi-story wood-framed apartment buildings with 20" pre-engineered floor trusses. The project included complex structural systems including girder trusses, continuous steel plates, and extensive Simpson hardware for holdowns and connectors.

InspectMind's AI review cross-checked structural details, header schedules, framing plans, and specifications—surfacing dimensional conflicts, incomplete details, and coordination issues that would have caused significant construction delays.

2021 IBCNDSAWC SDPWS

Sample Findings

Monumental CatchArea Increase Calculation Error

Area increase calculations used a multiplier of 4 for each floor instance but multiplied by 5 for the total—mathematical inconsistency that would have affected building area compliance.

"That would have been monumental. That's where we get burned—these little Excel formula errors."

MEPMEP Issues Caught

HighCondensate Line Undersized

Five AHUs connected to a single 3/4" condensate line. AI flagged this as likely undersized and recommended 1" line for capacity—both code compliance and best practice.

HighDFU Calculation Cross-Check

Cross-referenced drainage fixture units (DFUs) on pipe sizing against Florida Building Code plumbing requirements. Identified mismatches between fixture counts and pipe capacity.

StructuralStructural Issues Caught

CriticalRoof Holdown Stud Count Inconsistency

Roof holdown note "one stud per girder ply" contradicts minimum stud table requiring 2 studs minimum for 1-ply girders—could result in structural inadequacy at bearing locations.

CriticalInsufficient Fastener Length

2" Hilti DS fasteners specified through 1/2" steel plate plus 3" double wood plate—fastener cannot reach steel beam for proper connection.

CriticalPlaceholder Text in Hanger Specs

Details 14 and 15 show "XXXXX" placeholder text for Simpson hanger model numbers—incomplete design documents prevent procurement.

CriticalGirder Truss Size Mismatch

Header schedule shows Mark B as (4) 2x4 (3.5" deep) girder truss while Note 3 requires 20" deep floor system—impossible geometry.

CriticalBuilding Height Table Error

IBC table reference for Type R-2 buildings of Type 3A construction cited incorrect story limit (4 stories instead of 5). Referenced correct table but drew wrong conclusion.

Issue Categories

Wood Framing & Connections

Holdowns, trusses, stud counts, and wood connection hardware

Fasteners & Anchors

Fastener lengths, types, embedment, and anchor specifications

Headers & Beams

Header schedules, LVL sizes, girder trusses, and assembly patterns

Wall Framing

Stud sizing, wall depths, sheathing, and load-bearing identification

Structural Coordination

Grid lines, elevation conflicts, and cross-sheet consistency

Documentation Gaps

Placeholder text, missing details, and incomplete schedules

Why These Issues Matter

Structural Safety

Wood framing conflicts like undersized girder trusses and inadequate stud counts at bearing locations could result in structural failure under load.

Procurement Delays

Placeholder text for hardware specifications would halt procurement. Simpson connectors are long-lead items—incomplete specs cause weeks of delay.

1,497 issues surfaced in automated review
Placeholder text identified before bid
Header schedule vs. notes reconciliation
Fastener engagement verification

"All the MEP stuff seemed really spot-on. Cross-referencing DFUs with code requirements, the condensate line sizing—that's exactly the kind of checking we need. The area calculation error it caught would have been monumental. One issue like that pays for the entire review."

— Construction Manager, Florida

First $100 covered

Want This on Your Next Set?

Fast turnaround. Prioritized issue list with code references.

  • 5+ issues or full refund
  • Results in hours
  • No demo required

5+ issues or full refund · No demo required

Sample report: 282 issues found|Pricing after first check

227,181+ customer-visible issues across 2,000+ customer accounts